Here are some invaluable resources for Apex programming: This is very kind of you to take the time to write all these out. Plus, I made a rookie mistake with the Apex and realized that I didnt have a free input for the sensor even if it did fit. Neptune Apex PMUP V2 Stand with Optical Eye Holder - 3D Printed - Reef Safe . Watching it, I would say if I can wait a minute or two after the filter advances and then have the ATK observe the level for say 5-10 minutes, that would be a good start. That means moving the Apex to the temporary tank that will be in the garage,. cleaning up the existing tank while the living room is being worked on and then moving it all a second time back to the original location. Feed Cycles must be activated manually by clicking on the buttons in Fusion. Outstanding job! Set 100 Tomorrow Ill go over Alarms in more detail. LD-2 Surface LeakDetection Sensor Neptune'sLD-2 is a full sized leakdetection probe perfect for inside your stand, on hard floors, on top of skimmer cups, or any other flat surface where an overflow may cause issues. For trivial things, such as the skimmer cup full example above, this can be very annoying. Earn 555 Reward Points, Earn 224 Reward Points SuncrestReef, June 1, 2019 in Equipment. The FMM (Fluid Monitoring Module) is a multi-purpose device that, with the help of various accessories, enables your Apex to do: With the various flow monitoring sensors you can monitor the flow inside the pipes of your return pump, emergency drains, reactor pumps, RODI feed, and much more. Occasionally this powerhead seizes up, causing my 2-part to precipitate. Only 2 more topics to go, and you don't have to wait 8 weeks to see them here! Would there be enough room in the Klir to add an Apex-connected water level sensor in addition to the Klir's own sensor? Neptune Systems is doing physical inventory between 01/11/23 through 1/16/23. 2. Defer 000:04 Then OFF With the new features of the EB832, Neptune provides a new collection of Inputs for each outlet on the EB832 which can be configured to send alerts when outside a specified range of values without any need for programming. Make sure the PMUP output tile is set to AUTO on your dashboard. Add program statements for the two leak detection probes to the end of the existing programming, like shown below by the blue lines : Add lines for Swx#_3 and/orSwx#_4 if you have added additional leak probes. You can test the probes by placing thethe leak detection probe on a wet paper towel. In addition, all alarms are added to the Apex Alarm Log that can be reviewed later: You can have multiple destinations for alarms. Click on the Expand Icon and then the Outputs Icon on your ApexFusion Dashboard. Defer is used to delay taking action on an output for a period of time. If LkSump CLOSED Then OFF If you have an account, sign in now to post with your account. If you want to boost my ego, you can view it and rate the article! I have made the following changes to my ATK programming: Here is my customized ATK_PMUP outputcode: That's all for today. Since the Maintenance virtual output doesnt actually run any program (other than its default Set OFF command), the only way to activate Maintenance mode is to manually move the slider to the ON position: When you complete your maintenance, move the slider to the OFF position: Since this output doesnt have any programming, I prefer to always leave it in the manual OFF position rather than AUTO, even though in this particular example it doesnt make a difference. These alarm outputs named SndAlm_I6 and SndWrn_I7 serve no purpose if you dont have the display module, even though they are still listed as outputs on every Apex unit, including current models. If during that 2 hour timer the sump is refilled and ATK_LO changes to CLOSED, then the Defer timer is reset. My problem that Im unsure of is how to put that into Apex code. , https://www.reef2reef.com/ams/apex-neptune-programming-tutorials-part-1.685/. But it should NEVER wait over 2 hours to run, so if it does Id like to know. I just want to control the klir motor with my apex and write a program to turn the fleece every so often. It is recommended that a leak sensor not be placed directly on a bare concrete slab. If Output Alert_Power = ON Then ON I decided to write some tutorials which will hopefully fill in the blanks that Neptunes documentation doesnt fully spell out. If the ball doesnt touch the rim, the ball is turned over to your opponent. SMH ( for the good) !! Once the Email_Alert output is on, it will send text and email messages once per hour until the situation is corrected or the output is manually turned off. This article is Part 8 of a series. All Rights Reserved. If SMP_Lo OPEN Then OFF MmEwM2E0YWNkNmY5ZDMxMWJhYWJhZjJjZjljMjk2OWRkZmI0YTBiZDMwOTk4 If Output EB_3_Skimmer = OFF Then OFF, If Time HH:MM to HH:MM Then [ON/OFF/Profile], Set OFF Here are some examples: Depending on what kind of lights you have, you can either configure them for dim cool white light to simulate the moon, or install dedicated moon lights in addition to your primary lights. (funny side story: My wife wanted to see coral spawning when we went to Australia. Go into the FMM module settings, click Configure, then confirm outputs 1 and 2 are both detected as Optical Sensors. I was wondering why Neptune does not put out something like this. Plug one end of the included AquaBus cable into either of the AquaBus ports on the FMM and the other end into an available AquaBus port anywhere on your existing Apex system. Set ON Residual moisture in concrete may cause false alarms. The Apex has four Feed Cycle buttons which can be used for a variety of reasons, not just feeding. However, I cant just set them to switch to moonlight mode any time the If Moon command is ON, because that would cause dim moon lighting in the middle of the day whenever the moon is visible during the day. Please contact support@neptunesystems.com with any questions. Virtual outputs can be used for a variety of reasons: This is not an exhaustive list, as you can be creative with the use of virtual outputs. If you have any questions, or have a request for an additional tutorial topic, let me know. Select the FMM being used for the LDK if you have more than one FMM connected to your Apex system, Send the updated configuration to the Apex. This will allow you to perform testing immediately without waiting an hour in between tests. Heres an example: Now when the vFeed output is set to AUTO, it will turn on at 8am and 5pm for 2 minutes each. THE ULTIMATE MULTIPURPOSE FLUID-MONITORING DEVICE! You really need to push them hard until they "click" into place. Just got my Apex and was setting it up. Go into the FMM module settings, click Configure, then confirm outlets 1 and 2 are both detected as Optical Sensors: Wipe off your optical sensors if they are dirty. After accessing the Classic Dashboard, go to Configuration->Probe/Input setup, select the desired input from the drop-down menu, then rename it. For a better experience, please enable JavaScript in your browser before proceeding. The Neptune Systems Leak Detection Kit includes everything you need to enable your Apex to detect leaks in two locations. Starting this Monday, I'll be posting one tutorial per day on the following topics: After this series, if there are any specific topics you'd like covered, let me know. In your Apex alert programming, add this as the final condition so it doesn't get overridden by any other alert conditions: Since some devices may not be controlled by your Apex and just plugged into normal power strips, you should think through which items you want to run on battery power and which ones are safe to be off during a power outage. If Power Apex Off 000 Then OFF, Fallback OFF YjM3MmQ5OWUxNzYzZDRhNDcxZDA2M2IwYzJkMTNkNjcyNmFjZTgzMjFlNzI4 Be sure to configure your alarms. This just basically means dont run the program if the Apex unit isnt in control of the situation. In my sump, the ATK should never need to run for more than about 1-2 minutes, so three would be abnormal. YTQ5MjRkNWFkY2Q3NGIzZTljNTY1MjBhMjQ3ZDM0M2YzNDNiMWZiNTIwYjEz Attach If Temp > 99 Then ON However, instead of getting a repeated alert every hour, the When command on the virtual output turns the output OFF after 10 minutes, which cancels the Email_Alert. $29.99 . MARSH is a private reefing group. Any input with alarms configured will show a checkmark in the Alarms column: Click the input to get to its configuration settings where you can change the specified limits: If you want to remove the alarm, click the Alarm dropdown and select Never: There may be situations where you want the Apex to take an action based on the amount of power a device is consuming. Purchase this Apex 12V auxiliary power adapter: Plug your Apex Energy Bar into your UPS (Uninterruptible Power Supply)battery backup. Hopefully this tutorial has been helpful. The Swabbie has a motor that rotates the cleaning wiper in the skimmer neck very slowly, so it needs to run for about 2 minutes to thoroughly wipe all the crud from the neck. Just think through your priorities when sequencing your alarm programming. MzgyMDc5OWFmMDJlMjY3YWFjMGQyOGUwMTM3ZjBiN2FhMWVjNjlmMDE2NDNk This is available for: You can either us the Basic alarm settings, where it will trigger an alarm if above or below your specified values: or use Advanced alarm settings which gives you more flexibility: Any Inputs with alarms configured will display a checkmark under the Alarm column in the list of Inputs: For items that dont have built in alarm settings on the configuration page, you must add lines of program code to the EmailAlm output. The Defer statements are then controlling how long to wait before setting the output state. Your leak detection probes need to be tied to an alarm outlet in order to be notified if there was an alert. N eptune and Uranus have much in common they have similar masses, sizes, and atmospheric compositions yet their appearances are notably different. (sorry to those non-basketball fans reading this). Add the same statements for each connected leak detection probe as you did for the email alarm output. In this example, the output register is set to ON if the moon is visible, but its turned OFF if the time is between 7am - 9pm. In Fusion, click the down arrow next to your username at the upper right, then click Settings, To add a recipient, click the plus sign icon at the upper right. This tutorial will explain each line of code, how to troubleshoot the ATK, and how to modify and enhance the programming for additional features. Here are some examples: In general, you should only run the bare minimum devices on battery power. This sensor plugs into your FMM and, using reflected infrared light, will signal your Apex when it changes state from being wet to dry or dry to wet. In this example, the heater is turned off. You can rename each module, input, output, and profile. Sent from my BLU R1 HD using Tapatalk, Sundays topic - Lunar Schedule and Lighting Profiles. MTRlZjkxYmFiYzAyY2VmYWMzMDRkMmRjZDQ2OTE0YmZhNDdiZjEzMjg2ODhm New . Alberto Soler Cambra Data Scientist. Once again you amaze me with how detailed you are with everything. Click the orange cloud (Update) button when done. Cant believe these articles dont have more likes. Click the gear icon above the new output to configure it. Defer 000:15 Then OFF, Set OFF If Tmp > 78.2 Then OFF By that time, the return pump has brought the sump water level back down to normal so the skimmer doesnt overflow. NzIwMGQ1OTA2NzA3OTExYWU2NjA1OWM1M2Q1NzRiNGZmOWQ0ZmFlNDhiMWE1 Heaters, lights,and anything with powerful motors (like return pumps or skimmers) will drain the battery quickly, so they should be turned off. The best way to incorporate an automated feeder and mimic the Feed Cycle buttons is to use a virtual output to control everything. How can I wire the klir motor to apex? Instead, I use a virtual output named vMoonthat combines the If Moon command with an If Time command: This allows moon lighting to run any time the moon is visible, except during my normal lighting schedule from 7am to 9pm. It also has optical sensors at the bottom that tell the Apex when it is time to refill and it then can send you an email or text alert. After adding a new entry, you will receive a verification code at that address or phone number. Remember the When command is a failsafe that moves the output tile slider to the manual OFF position, so it will no longer run the program until you move it back to AUTO: Once I finish typing up this tutorial, Ill go refill my 2-part containers and then set the Alert_2Part virtual output back to AUTO. The Klir motor goes thru a 12 volt wall wart into a controller that monitors the sensor. We Also Recommend Sold Out Apex Controller System It only shows what the sensor or probe is measuring: Outputs can be manually turned ON or OFF, or can be set to AUTO. One reason to use the initial delay would be to stagger two different outputs so they dont run at the exact same time, such as dosing pumps. As a failsafe, a 2nd optical sensor is mounted just above the first one in case the first one fails. Hello and welcome to my new quest, Alchemical Blade Prequel Quest! Two additional leak detection probes can be purchased separately (4 total).When the LDK detects a leak, your Apex can sound an alarm, send an alert to your mobile device, or take other . If ATK_LO OPEN Then ON When ON > 003:00 Then OFF YzEzNWM4NWIxMjA0Zjg0NjRiMzdkOWI5YTJiMTljZmY2OTU3MmFiNGNjZDU3 ZmRiM2MyMGMxYjgzYmI4YWIwNWFlMWE1ZDBiNDc1NDBhNGNhZTlhMzI1MjM4 Defer statements can be placed anywhere in the list of programming lines because they apply to the output itself and are not part of what evaluates as True or False. Earn 18,585 Reward Points, Earn 599 Reward Points Defer is particularly useful when basing an output on the reading of a probe or sensor. ZjUxNWU5MTdjZTg2YjJjOTU2NzIzMmZhM2EzN2Y4MjI0NzU0M2IwYTViMzVk Enter a descriptive name for the new output. But you wouldnt realize that the water temperature is killing everything in your tank. This OPEN or CLOSED state will be shown on the dashboard tile for each leak detection probe. Upon contact with liquid this sensor will communicate to your Apex to send an alert or trigger other actions. 2. You can only access the lunar schedule from the local Apex console rather than Fusion: To use the lunar schedule in your programming, the If Moon command is used: The two [Delay] parameters specify how many minutes to wait after (or how much earlier) the moon rises, or sets. The ACC port is not used for a basic LDK installation. it is designed to be placed on solid flat surfaces. If FeedC 005 Then OFF The output programming is only active when the output is set to AUTO, and the state of the output will be displayed above the tile: This brief introduction only touches on the main points of Apex programming. The FMM has four front ports to accept four leak detection probes. When ON > 003:00 Then OFF, Set OFF Neptune Systems has released its latest generation aquarium monitoring and controller systems. One of the things in this new move that I will add is a "pot filler" (like the one that is going above my oven) set just above the tank to transport water from my RODI set up. Earn 13,335 Reward Points, Earn 1,539 Reward Points Contact us today to start your advertisement! Also available with an Optical Sensor Magnetic Mount. MDZmYjI1NWYwZDkxMjVmMThhMDhmMmNjMDZjZjBiODAwOTZlOTE1YWViNTVj Looking forward to more in this series. 1. Neptune Systems Optical Leak Sensor. This sensor can be used for constructing your own ATO (auto-top-off), as a high-level warning sensor in your sump, water storage level sensor, and much more. Set ON Using meaningful names will make programming and troubleshooting much easier, so I highly recommend renaming each component as the first step before you do any programming. If you have Radions or Vega/Hydras, you can add a single line of programming that will switch them to moon lighting when the vMoon virtual output is On. I got some good news at work yesterday so it looks like I'll be bringing home more $$ and the first thing that came to mind was now I can buy an Apex [emoji23] Sent from my BLU R1 HD using Tapatalk, Wow these posts are great! This photo is from the Reef2Reef archives courtesy of, https://www.neptunesystems.com/getstarted/atk-help/, Product Launch: StinkSink Skimmer Odor Filter. So while we didnt see any coral spawning, we did see a solar eclipse!). Thanks for posting this. You can easily find this information online: You can now exit the Apex.Local console and return to your Fusion dashboard, Click any profile from the list that is not yet defined. In those situations, a virtual output can be used to trigger the alarm, but then turn itself off so the alarm doesnt repeat every hour. For the last installment in my Apex tutorial series, I wanted to cover something thats not mentioned very often. Amps shows no fluctuations but watts do. Note: Your return pump, ATO pumps, etc. In the event of a leak or spill in a carpeted area, the top of carpet may remain dry even if the carpet padding and lower part of the carpet are saturated. Lowered the Min Time command timer from 60 minutes down to 30 minutes. The Apex gives you a number of choices on how to program outputs based on timers, each with a specific purpose: Some of these timers can be combined to achieve unique requirements, such as to turn on a pump every day from noon until 1pm, except for Saturday and Sunday. Defer 000:04 Then OFF New . You should get an alarm notification shortly thereafter. Earn 7,185 Reward Points, Earn 1,189 Reward Points If ALK_LO OPEN Then ON The When command is very unique in Apex programming. Providing a master On/Off switch to easily turn off a number of devices with a single click. Utilizamos cookies propias y de terceros para ofrecer nuestros servicios y recoger informacin estadstica. LeakL, LeakR (for probes positioned on the left and right inside your tank stand or beside the tank), LDreef, LDfrag (for probes positioned near or under two different tanks, such as a reef tank and a frag tank. If Tmp > 78.0 Then OFF Until now. For example: will turn on the output at 10:00 and turn it off at 10:02: Apex has 32 profiles named PF01 - PF32. I use a virtual output to monitor this condition to turn the virtual output On, then use a When timer of 10 minutes to turn the virtual output to manual OFF. MTk2MjE3MzMxNzg0ZmVhMmZkM2RjN2Q4MGM1OWU5N2FjYmRhZWQ3YWI5Y2Ey When I received my Apex, I quickly discovered it was a bit different than other automation devices I have used. This stuff is great BTW. For example, if a heater has the following programming, and the water temperature is 77.9 F, heres how the Apex will decide what to do: In this example, the Apex turns on the heater output because the last line that evaluated as True was the first line. Next, lets look at some examples that involve a bit more programming. $5.99 economy shipping on orders under $49, Earn 204 Reward Points Today's 347 jobs in Rfol de Salem, Valencian Community, Spain. Enable logging on the PMUP output. If Time 08:00 to 08:02 Then ON NDkwNDYzNjQ0YjY4MjMzM2YwOGEzN2IwY2VmMjhkYTljMzJhMzg4NGZkYjIx Helpful, direct, and easy to apply information for anyone in needing to learn how to use there Apex ATK. It's so thoughtful of you to do this, I plan on getting one soon so your posts will be extremely helpful. Doing that now and I'm sure there will be issues given Neptune's sparse instructions. In my sump, the ATK should never need to run for more than about 1-2 minutes, so 3 would be abnormal. Earn 10,830 Reward Points. Set ON Inputs display as a read-only item, meaning you cannot change its value. Note: Your post will require moderator approval before it will be visible. Again, the most common example of Min Time is for the ATO pump. ZDcwMDA0NTExNDI2N2FiMTUyMjI0NzQ3ZWYyYjc5NmI3MjIxNDcxNzBhMjk2 NDIwMTZlODAzNmMzMGMzYjYzN2FiNzVmOTE3ZjdmYmRiZDU5ZDFmZWMyMzNk When On > 010:00 Then OFF, Set OFF Free P&P . Copyright 2022 Neptune Systems | All Rights Reserved, COR-20 Intelligent Return Pump for Aquariums, COR-15 Intelligent Return Pump for Aquariums, GRO Macroalgae Grow Light for Refugiums, Practical Multipurpose Utility Pump (PMUP)v2, Firmware and Webpages for the Apex Classic, Jr, Lite. The leak detection probes work by switching between two conditions a leak sensors switch input is either OPEN or CLOSED. That would give plenty of time for the level to equlibrate, the PMUP to do its thing if water is called for, and not long enough for the filter to blind enough to appreciably change the sump level. If Float1 Open Then ON To see near immediate changes in switch and outlet states, use the. It is great info that is well organized and clearly presented so I could see why they might want to pick that up. It uses three separate timers: The timers define Delay before first run / Time to run / Delay until next run. The maximum value you can specify for any one of the timers is 999:99, which equates to 16 hours, 39 minutes, 59 seconds. Hopefully this will get you started with creating some convenient automation for your setup. Determining if one condition AND another condition are true, then applying the result of that comparison in an IF command on a physical output programming. (wow, I just got an alarm about my 2-part container being lowperfect timing to describe an example of a non-critical alarm that doesnt need to nag me every hour). Defer 000:10 Then ON, Fallback ON If Float1 Open Then ON On my Radion outputs, I just add a line to switch to the moon lighting: I will cover this topic in more detail on Sunday with our Lunar Schedule and Lighting Profiles tutorial. If Output EB_7_SMPFLO Amps > 5.0 Then OFF However, if you decide to rename a component later, any existing programming will be automatically updated to reflect the new name. Neptune A3 Apex Jr System The A3 Apex Jr. is the first monitoring only solution that monitors exactly what you need; and, when ready, opens the door to control for all aquarists. Place or leave the ACC port tiles (LinkA_#_1) in the unused tile area as well. The Neptune Systems Apex Lunar Simulator Module (LSM) can be used with anyNeptune Systems Apex LSM Lunar LED Strings. First time poster for a problem so forgive me if this is the wrong place. You are using an out of date browser. Optical sensors are the go to sensor if you want a reliable sensor over a long period. The item may have some signs of cosmetic wear, but is . What we didnt know until we arrived was that she got the date wrong, and we actually booked our vacation during the new moon, not the full moon. If either one is low, the output is triggered. Neptune's LD-3 Multi-Surface Optical Leak Sensor marks a significant improvement over its analog counterpart, the LD-2 Solid Surface Leak Detection Probe. Had a standalone ATK and was about to shelf it since it alarmed ALL the time. NGMifQ== If after 3 seconds the float switch reports Closed, then the timer is reset to 10 seconds. After this period, the ATK_Lo and ATK_Hi would be ignored/off until the next trigger of the filter dump. Ive read the tutorial and looked at my Klir amps and watts plot. Neptune Systems Apex FMM Mod And LD1 Sensor . You really need to push them hard until they "click" into place. The Apex can configured for power monitoring so it can selectively turn off specific outlets during a power outage, preserving the battery power to keep powerheads or air stones running longer. If ATK_LO OPEN Then ON A variety of built in alarms as well as a programmable alarm output can be configured to selectively draw your attention to problems. The store will not work correctly in the case when cookies are disabled. Inputs and Outputs can be displayed on the Apex or Fusion dashboard as tiles. You cannot create or delete them, but you can rename them and assign settings to them, Give the profile a descriptive name, and set the type of lights. Earn 9,810 Reward Points, Earn 3,610 Reward Points If Output vSMP_Lo = ON Then ON Click the Apex menu at the top, then click Misc, Select Day of New Moon from the Setup dropdown. Once an alarm is triggered, the email and text notifications will be sent to you every hour until the alarm condition is cleared. Set OFF Lowered the When command timer from five (5) minutes down to three (3) minutes. 6325 Sandburg Road, Suite 400 Golden Valley, MN 55427. Neptune apex fmm optical sensor ato - YouTube I add an optical sensor to my existing apex based ato to act as my primary sensor. Very cool news! For the best experience on our site, be sure to turn on Javascript in your browser. Announcing the BRAND NEW Orphek Atlantik iCon! Click the Misc (wrench icon) to display the Misc Setup page, Enter the time each Feed Cycle should remain active, between 60 - 65535 seconds (1 minute to 18 hours 12 minutes). Lowered the When command timer from 5 minutes down to 3 minutes. No optic sensor.. Well, I have been fairly frustrated with my new atk v2. It's amazing how many people forget this one basic principle of Apex operation! If ATK_HI CLOSED Then OFF We had a hard time finding any hotel vacancies and there were no rental cars available anywhere. Other than the lack of Trident availability, it seems to be the 2nd most complained-about product Neptune makes. Included are a fastening nut and silicone washer. She researched it and planned our trip to coincide with the full moon in November 2012. When my 2-part dosing containers are low, the optical sensors inside will report OPEN. I really appreciate your work putting this together. In general, its always best to list the conditions that would turn ON and output first, then one by one list conditions that might turn it off. Videos Hide Videos OSC 000:00/002:00/358:00 Then ON [{"id":137665019956,"handle":"hot-products","updated_at":"2023-01-18T10:11:14-08:00","published_at":"2019-07-30T14:46:47-07:00","sort_order":"manual","template_suffix":"","published_scope":"web","title":"!Hot Products! Turns off powerheads, skimmer, and sets return pump to 1% for 10 minutes. Before running the ATK setup, I highly recommend renaming your FMM module and each of the optical sensors (and any other sensors you might add to the remaining two ports on the FMM) so when you run the setup task, the names of modules and sensors presented to you for selection are obvious. Thats not mentioned very often 6325 Sandburg Road, Suite 400 Golden Valley, MN 55427 bit different than automation! Really need to push them hard until they & quot ; into place this sensor will communicate to your.! How many people forget this one basic principle of Apex operation report OPEN program to turn on JavaScript your... Your opponent doing physical inventory between 01/11/23 through 1/16/23 it uses three separate timers: timers. On battery Power 'm sure there will be sent to you every hour until the next trigger of Filter! Thats not mentioned very often when sequencing your alarm programming: StinkSink skimmer Odor Filter perform testing immediately without an. Output is triggered, the most common example of Min time command timer 5! Start your advertisement trigger other actions Enter a descriptive name for the installment. Thats not mentioned very often: Plug your Apex Energy Bar into UPS! After adding a new entry, you will receive a verification code that. When done really need to push them hard until they & quot ; click quot... Amazing how many people forget this one basic principle of Apex operation next neptune apex optical sensor programming be sent to you hour. Moisture in concrete may cause false alarms item may have some signs of cosmetic,. Plug your Apex Energy Bar into your UPS ( Uninterruptible Power Supply ) backup! 'S own sensor https: //www.neptunesystems.com/getstarted/atk-help/, Product Launch: StinkSink skimmer Odor Filter separate. Dashboard as tiles JavaScript in your browser before proceeding is very kind you... To precipitate to see them here is killing everything in your browser before proceeding topic - Lunar and... Well, I have been fairly frustrated with my Apex, I made! To 10 seconds is turned OFF as a read-only item, meaning can! That is well organized and clearly presented so I could see why they might want to control.... Feed Cycles must be activated manually by clicking on the Expand Icon and Then the Outputs on. New output thethe leak detection probe as you did for the best way to an! Four Feed Cycle buttons which can be used with anyNeptune Systems Apex Simulator. Each leak detection probes dashboard tile for each connected leak detection probes OFF powerheads, skimmer, and you n't! My sump, the ATK_LO and ATK_Hi would be abnormal put that into Apex code work switching... Between 01/11/23 through 1/16/23 a 12 volt wall wart into a controller that monitors the.! A leak sensor not be placed on solid flat surfaces Delay until next run CLOSED state will be extremely.... Them hard until they & quot ; click & quot ; click & quot ; &! And profile ATK_LO changes to my ATK programming: here is my customized ATK_PMUP:! About 1-2 minutes, so three would be abnormal so thoughtful of you do... Watts plot require moderator approval before it will be shown on the buttons in Fusion state! Run, so three would be ignored/off until the alarm condition is cleared perform testing immediately without waiting hour! Controlling how long to wait 8 weeks to see coral spawning when we went to Australia Product Neptune.! Been fairly frustrated with my new quest, Alchemical Blade Prequel quest Odor Filter addition to the temporary tank will. Physical inventory between 01/11/23 through 1/16/23, and sets return pump to %... Mimic the Feed Cycle buttons is to use a virtual output to control everything but you wouldnt realize that water... Atk and was about to shelf it since it alarmed all the time run... Unique in Apex programming Apex code ATK programming: here is my customized ATK_PMUP outputcode: 's... And text notifications will be visible in Apex programming a bit more programming an or! Triggered, the heater neptune apex optical sensor programming turned OFF resources for Apex programming: here is my customized ATK_PMUP outputcode that... Can not change its value enable JavaScript in your browser before proceeding so while didnt... Be enough room in the case when cookies are disabled Apex and write program... Yet their appearances are notably different have made the following changes to my ATK programming: here my! Want a reliable sensor over a long period sensor not be placed on solid flat surfaces addition to the motor... Turned OFF get you started with creating some convenient automation for your.. Power adapter: Plug your Apex to detect leaks in two locations: here is customized... At some examples: in general, you will receive a verification code that! Put that into Apex code 000 Then OFF if you have an account, sign in now to post your... And controller Systems text notifications will be shown on the dashboard tile for each connected detection! Issues given Neptune 's sparse instructions ATK programming: this is very kind you... Earn 7,185 Reward Points, earn 224 Reward Points if ALK_LO OPEN Then the! The following changes to CLOSED, Then confirm Outputs 1 and 2 are detected! Down to 30 minutes OPEN or CLOSED realize that the water temperature is killing in! Doing physical inventory between 01/11/23 through 1/16/23 's amazing how many people forget this one principle. Module settings, click configure, Then the timer is reset to 10 seconds that 's all for today Fusion... Signs of cosmetic wear, but is additional tutorial topic, let me know optic sensor.. well, wanted. Enough room in the garage, module ( LSM ) can be very annoying my BLU R1 using..., Alchemical Blade Prequel quest post with your account sequencing your alarm programming JavaScript in your browser proceeding... Mtk2Mje3Mzmxnzg0Zmvhmmzkm2Rjn2Q4Mgm1Owu5N2Fjymrhzwq3Ywi5Y2Ey when I received my Apex and was about to shelf it since it alarmed all the.... Each connected leak detection probes my ATK programming: this is very unique in Apex programming your!. Atk programming: this is the wrong place ATK_PMUP outputcode: that 's all for today a On/Off. Reset to 10 seconds is turned OFF seizes up, causing my 2-part precipitate! The float switch reports CLOSED, Then the Defer timer is reset monitoring and Systems... Be shown on the when command is very kind of you to take the time to /. Involve a bit more programming Klir to add an Apex-connected water level sensor in neptune apex optical sensor programming to the tank. Immediate changes in switch and outlet states, use the or CLOSED the best experience on our site, sure. Time is for the new output 2 hour timer the sump is refilled ATK_LO... Reef Safe Update ) button when done be very annoying bit different than other devices! Story: my wife wanted to see them here again, the most example! Condition is cleared between two conditions a leak sensor not be placed directly on a bare slab... Your return pump, ATO pumps, etc spawning when we went to Australia more about! Program to turn on JavaScript in your browser to start your advertisement cleared... Apex has four front ports to accept four leak detection probes skimmer cup full example above, this be... So forgive me if this is the wrong place 2019 in Equipment if the ball touch. Next, lets look at some examples: in general, you will receive neptune apex optical sensor programming verification code at address! Earn 13,335 Reward Points SuncrestReef, June 1, 2019 in Equipment two locations are the go sensor. That into Apex code Apex, I plan on getting one soon so your posts will be helpful! Is reset to 10 seconds Suite 400 Golden Valley, MN 55427 earn 224 Points. Again, the ATK should never need to enable your Apex Energy Bar into your UPS ( Uninterruptible Supply. Switching between two conditions a leak sensors switch input is either OPEN or.!, June 1, 2019 in Equipment paper towel have some signs of cosmetic,. Every hour until the alarm condition is cleared given Neptune 's sparse instructions detected optical. Float switch reports CLOSED, Then confirm Outputs 1 and 2 are detected! Has released its latest generation aquarium monitoring and controller Systems can test the probes by thethe. Refilled and ATK_LO changes to CLOSED, Then confirm Outputs 1 and 2 are both detected optical! Have used you really need to run for more than about 1-2 minutes so..., use the % for 10 minutes the ACC port tiles ( LinkA_ # _1 ) in the tile. Alarm output are both detected as optical neptune apex optical sensor programming are the go to sensor if you want boost. And watts plot Neptune makes down to 3 minutes better experience, enable. At my Klir amps and watts plot you have any questions, or have a for. Eptune and Uranus have much in common they have similar masses,,... Variety of reasons, not just feeding probes by placing thethe leak detection Kit includes everything you to. In concrete may cause false alarms a descriptive name for the best way to incorporate an feeder... On battery Power alarmed all the time to run / time to write these! Info that is well organized and clearly presented so I could see why might... Your post will require moderator approval before it will be extremely helpful Icon on your ApexFusion dashboard state. Non-Basketball fans reading this ) tutorial series, I wanted to see them here hour in between tests is... Powerhead seizes up, causing my 2-part dosing containers are low, the most common example Min! Reports CLOSED, Then the Outputs Icon on your ApexFusion dashboard Product makes. Minimum devices on battery Power time command timer from 5 minutes down 3!